plas
Log In

POM DURACON®  GH-25D DAICEL MALAYSIA

32
  • Properties:
    High rigidityHigh temperature resistanFiller: Glass fiber reinf25% filler by weight
  • Usages:
    Automotive ApplicationsElectrical applications
  • Compare View Prices

Technical Data Sheet

flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94HB
mechanical propertiesTest ConditionTest MethodTest Result
Wear factor0.060MPa,0.15m/sec7JISK721810000 10^-8mm³/N·m
Wear factor0.49MPa,0.30m/sec6JISK72187000 10^-8mm³/N·m
Wear factor0.49MPa,0.30m/sec5JISK7218400 10^-8mm³/N·m
bending strengthISO 178196 Mpa
Bending modulusISO 1787900 Mpa
Tensile strainBreakISO 527-22.4 %
tensile strengthISO 527-2136 Mpa
Tensile modulusISO 527-28500 Mpa
Wear factor0.060MPa,0.15m/sec4JISK7218300 10^-8mm³/N·m
Friction coefficientSteel - Dynamic3JISK72180.60
Friction coefficientDynamic2JISK72180.37
thermal performanceTest ConditionTest MethodTest Result
Linear coefficient of thermal expansionTD:23to55°CInternal Method9E-05 cm/cm/°C
Linear coefficient of thermal expansionMD:23to55°CInternal Method3E-05 cm/cm/°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A162 °C
Physical propertiesTest ConditionTest MethodTest Result
Water absorption rate23°C,24hrISO 620.60 %
Melt Volume Flow Rate (MVR)190°C/2.16kgISO 11339.00 cm3/10min
melt mass-flow rate190°C/2.16kgISO 113312 g/10min
Electrical performanceTest ConditionTest MethodTest Result
Dielectric strength3.00mmIEC 60243-124 KV/mm
Volume resistivityIEC 600935E+13 ohms·cm
Surface resistivityIEC 600934E+16 ohms
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessM-ScaleISO 2039-295
Supplementary InformationTest ConditionTest MethodTest Result
ColourNumberCF3500/CD3501
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.