PA6 YH-3400 SINOPEC BALING
76
Form:Granules | Grade:Extrusion grade
Properties:
high viscosity High viscosity
Typical Applications:
Packaging filmIndustrial applicationsSuitable for industrial silkUses such as packaging film and high-strength wear
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Packaging film | Industrial applications | Suitable for industrial silk | Uses such as packaging film and high-strength wear |
| Properties: | high viscosity | High viscosity |
Certificates
No Data...
Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| water content | --- | GB 6509-86 | <0.07 | % |
| density | --- | GB 1033-86 | 1.157 | g/cm³ |
| Relative viscosity | --- | GB/T 1632-93 | 3.40±0.03 | --- |
| Monomer content | --- | 色谱内标法 | <0.3 | % |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | --- | GB 9342-88 | 28.3 | kJ/m² |
| bending strength | --- | GB 9341-88 | 84.9 | Mpa |
| tensile strength | --- | GB 1040-92 | 64.6 | Mpa |
| Shore hardness | --- | GB 9341-88 | 69.2 | R |
| Bending modulus | --- | GB 9341-88 | 1992 | Mpa |
| Elongation at Break | --- | GB 1040-92 | 231.3 | % |
| Shrinkage rate | --- | GB/T 1043-93 | 1.42 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | --HDT | --- | 75.0 | °C |
| Melting temperature | --- | --- | 219-225 | °C |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric constant | --- | GB 1044-70 | 1.5 | --- |
| Volume resistivity | --- | GB 1044-70 | 2.7*1013 | Ω |
| Surface resistivity | --- | GB 1044-70 | 6.0*1013 | Ω |
| --- | GB 1044-70 | 7.3*1011 | Ω | |
| Volume resistivity | --- | GB 1044-70 | 2.5*1015 | Ω.cm |
| Dielectric loss | --Tangent | GB 1044-70 | 4.0*10-2 | --- |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.