Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.32 g/cm³ |
Water absorption rate | | ASTM D570 | 0.50 % |
Filling analysis | Test Condition | Test Method | Test Result |
---|
melt viscosity | | ASTM D3835 | 500 Pa·s |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
elongation | | ASTM D638 | 75 % |
elongation | | ASTM D638 | 35 % |
Flexural modulus | | ASTM D790 | 3300 MPa |
bending strength | | ASTM D790 | 134 MPa |
compressive strength | | ASTM D695 | 118 MPa |
shear strength | | ASTM D732 | 82.0 MPa |
Tensile modulus | | ASTM D638 | 3100 MPa |
tensile strength | | ASTM D638 | 94.0 MPa |
elongation | | ASTM D638 | 6.7 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 75 J/m |
Suspended wall beam without notch impact strength | | ASTM D4812 | 无断裂 |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTM D149 | 180 kV/mm |
dielectric constant | | ASTM D150 | 3.21 |
dielectric constant | | ASTM D150 | 3.23 |
dielectric constant | | ASTM D150 | 3.18 |
Dissipation Factor | | ASTM D150 | 2E-03 |
Dissipation Factor | | ASTM D150 | 1E-03 |
Dissipation Factor | | ASTM D150 | 6E-03 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 252 °C |
Glass Transition Temperature | | ASTM D3418 | 158 °C |
melting temperature | | ASTM D3418 | 340 °C |
specific heat | | DSC | 1650 J/kg/°C |
specific heat | | DSC | 1660 J/kg/°C |
thermal conductivity | | ASTME1530 | 0.22 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.