PP CELSTRAN® PP-GF60-0403
23
- Properties:enhanceHigh temperature resistan
- Usages:Automotive ApplicationsElectrical applications
Technical Data Sheet
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO527-2/1A/1 | 15000 Mpa | |
ISO527-2/1A | 9500 Mpa | ||
Tensile stress | ISO527-2/1A/5 | 145 Mpa | |
ISO527-2/1A | 85.0 Mpa | ||
Tensile strain | ISO527-2/1A/5 | 1.5 % | |
ISO527-2/1A | 2.0 % | ||
Flexural modulus | ISO178 | 16000 Mpa | |
ISO178 | 11000 Mpa | ||
Bending stress | ISO178 | 240 Mpa | |
ISO178 | 136 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO179/1eU | 70 kJ/m² | |
ISO179/1eU | 68 kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ISO75-2/A | 160 °C | ||
melting temperature | ISO11357-3 | 168 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.