PC 4800-10 STYRON TAIWAN
10
Form:Granules | Grade:Flame retardant grade
Properties:
High impact resistance
Typical Applications:
Electrical fieldElectronic field
Product Description
Certificates(0)
Datasheet
Alternative Model(1)
Product Description
| Typical Applications: | Electrical field | Electronic field |
| Properties: | High impact resistance |
Certificates
No Data...
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Glow wire combustion index (GWFI) | 2.0mm | IEC 695-2-1 | 960 | °C |
| Limiting Oxygen Index (LOI) | ASTM D-2863 | 36 | % | |
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 300℃/1.2kg | ASTM D-1238 | 10 | g/10min |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Break | ASTM D-638 | 59 | Mpa |
| Impact strength of cantilever beam gap | 总能量@23℃ | ASTM D-1822 | 631 | KJ/m |
| Rockwell hardness | ASTM D-785 | 59 | M Scale | |
| tensile strength | Yield | ASTM D-638 | 61 | Mpa |
| Bending modulus | ASTM D-790 | 2330 | Mpa | |
| bending strength | ASTM D-790 | 98 | Mpa | |
| elongation | Break | ASTM D-638 | 115 | % |
| Impact strength of cantilever beam gap | 23℃ | ASTM D-256 | 未破裂 | |
| Tensile modulus | ASTM D-638 | 2380 | Mpa | |
| Impact strength of cantilever beam gap | 23℃ | ASTM D-256 | 694 | J/m |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | 50℃/hr,50n重 | ASTM D-1525 | 151 | °C |
| Hot deformation temperature | Annealed@0.45MPa | ASTM D-648 | 137 | °C |
| Shrinkage rate | ASTM D-696 | 65×10 | mm/mm/℃ | |
| Hot deformation temperature | Unannealed@1.82MPa | ASTM D-648 | 127 | °C |
| Ball indentation temperature | IEC 598-1 | >125 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | ASTM D-955 | 0.005-0.007 | mm/mm | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the Leakage Traceability Index (CTI) | 2.0mm | IEC 112 | 225 | V |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.