physical property | Test Condition | Test Method | Test Result |
---|
Linear forming shrinkage rate | | ASTM D-955 | 0.04-0.07 mm/mm |
Basic performance | Test Condition | Test Method | Test Result |
---|
density | | ASTM D-792 | 1.25 g/cm |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
| | ASTM D-790 | 80 MPa |
Flexural modulus | | ASTM D-790 | 2300 MPa |
Rockwell hardness | | | 105 |
Tensile strength at break | | ASTM D-638 | 62 MPa |
Impact strength of cantilever beam gap | | ASTM D-250 | 40 KJ/m |
elongation | Break | ASTM D-638 | 100 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTM D-149 | 16 KV/mm |
Surface Resistivity | | ASTM D-257 | 10 Ω |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Flame retardancy | | UL 94 | V0 |
| | ASTM D-648 | 130 ℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.