PA6 6V0M DOMO CHEM GERMANY
158
Form:Granules | Grade:Flame retardant grade
Properties:
Flame retardantHalogen-free
Typical Applications:
Automotive External PartsAutomotive interior partsElectronic fieldElectrical field
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive External Parts | Automotive interior parts | Electronic field | Electrical field |
| Properties: | Flame retardant | Halogen-free |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 3.0 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 80 | kJ/m² |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 3.0 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Burning wire flammability index | 1.0to3.0mm | IEC 60695-2-12 | 960 | °C |
| UL flame retardant rating | 0.8mm | UL 94 | V-0 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2/1 | 3400 | Mpa | |
| tensile strength | Yield | ISO 527-2/50 | 80.0 | Mpa |
| Break | ISO 527-2/50 | 65.0 | Mpa | |
| Tensile strain | Yield | ISO 527-2/50 | 8.0 | % |
| Break | ISO 527-2/50 | 15 | % | |
| Bending modulus | ISO 178 | 3200 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 180 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 70.0 | °C | |
| Vicat softening temperature | ISO 306/B50 | 205 | °C | |
| Melting temperature | ISO 11357-3 | 218to222 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.17 | g/cm³ | |
| Water absorption rate | Saturation,23°C | ISO 62 | 9.0 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1E+13 | ohms | |
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.