ABS SERG1 BK DAICEL JAPAN
29
Form:Granules | Grade:Enhanced level
Properties:
Flame retardantenhanceGlass fiber reinforcedEnhanced level10% short glass fiber reiEnhanced level10% short glass fiber rei
Typical Applications:
Decorative componentsShellHousehold goodsSuitable for exterior decorative materialsCar chargerInjection molded products for telephone racks and
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Decorative components | Shell | Household goods | Suitable for exterior decorative materials | Car charger | Injection molded products for telephone racks and |
| Properties: | Flame retardant | enhance | Glass fiber reinforced | Enhanced level | 10% short glass fiber rei | Enhanced level | 10% short glass fiber rei |
Certificates

Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Water absorption rate | ISO 62 | 0.3 | % | |
| density | ISO 1183 | 1.30 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | ISO 527 | 75 | Mpa | |
| bending strength | ISO 178 | 110 | Mpa | |
| Bending modulus | ISO 178 | 4700 | Mpa | |
| Charpy Notched Impact Strength | 23℃ | ISO 179/1eA | 8 | KJ/m |
| -30℃ | ISO 179/1eA | 5 | KJ/m | |
| Impact strength of cantilever beam gap | 23℃,6.4mm | ASTM D-256 | 80 | J/m |
| -30℃,6.4mm | ASTM D-256 | 40 | J/m | |
| Rockwell hardness | ISO 2039 | R114 | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.80MPa,12.7mm | ISO 75/A | 86 | °C |
| 1.82MPa,12.7mm | ASTM D-648 | 94 | °C | |
| Vicat softening temperature | 50N,50℃/h | ISO 306/B50 | 91 | °C |
| 9.8N,50℃/h | ASTM D-1525 | 100 | °C | |
| Linear coefficient of thermal expansion | Flow | ISO 11359 | 5 | ×10 |
| Combustibility | UL 94 | V-0 | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | ASTM D-955 | 0.2-0.5 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Arc resistance | 3.0mm | ASTM D-495 | 10 | sec |
| 3.0mm | ASTM D-495 | PLC_7 | ||
| Dielectric strength | 1.5mm | ASTM D-149 | 34 | MV/m |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.