PA66 A 205F

67

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO1183/A1.14 g/cm³
Water absorption rateISO621.2 %
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94V-2
UL flame retardant ratingUL94V-2
UL flame retardant ratingUL94V-2
UL flame retardant ratingUL94V-2
GlowWireFlammability IndexIEC60695-2-12850 °C
Limiting Oxygen IndexISO4589-229 %
FrenchFireIndexNFF16-101F2
FrenchSmokeIndexNFF16-101I3
Supplementary InformationTest ConditionTest MethodTest Result
EuropeanRailwaysCertificationsEN45545-2HL2
EuropeanRailwaysCertificationsEN45545-2HL2
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO527-2/1A3200 Mpa
tensile strengthASTMD63885.0 Mpa
Tensile stressISO527-2/1A85.0 Mpa
Tensile stressISO527-2/1A60.0 Mpa
Tensile strainISO527-24.0 %
elongationASTMD63825 %
Tensile strainISO527-250 %
Flexural modulusASTMD7903350 Mpa
Flexural modulusISO1783000 Mpa
bending strengthASTMD790125 Mpa
Bending stressISO178120 Mpa
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO179/1eA5.0 kJ/m²
Impact strength of simply supported beam without notchISO179/1eUNoBreak
Impact strength of cantilever beam gapASTMD25680 J/m
Impact strength of cantilever beam gapISO1805.0 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC600935E+15 ohms
Volume resistivityIEC600931E+15 ohms·cm
dielectric strengthIEC60243-127 KV/mm
IEC602502.90
Dissipation FactorIEC602500.030
CTIIEC60112600 V
CTIIEC60112550 V
Thermal performanceTest ConditionTest MethodTest Result
ISO75-2/Bf205 °C
ASTMD64880.0 °C
ISO75-2/Af65.0 °C
melting temperatureISO11357-3263 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.