Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | ASTM D570 | 0.10 % | |
density | ASTM D792 | 1.63 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ASTM D638 | 52.0 MPa | |
elongation | Break | ASTM D638 | 3.0 % |
Flexural modulus | ASTM D790 | 4800 MPa | |
bending strength | ASTM D790 | 90.0 MPa |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 380 °C | |
Linear coefficient of thermal expansion | ASTM D696 | 3.8E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.