Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792 | 1.20 g/cm³ | |
Specific volume | ASTM D792 | 0.830 cm³/g | |
density | ASTM D792 | 1.19 g/cm³ | |
ISO 1183 | 1.20 g/cm³ | ||
melt mass-flow rate | ASTM D1238 | 6.0 g/10min | |
ASTM D1238 | 30 g/10min | ||
Melt volume flow rate | ISO 1133 | 29.0 cm³/10min | |
Shrinkage rate | 内部方法 | 0.60to0.80 % | |
Water absorption rate | ASTM D570 | 0.16 % | |
ISO 62 | 0.16 % | ||
ISO 62 | 0.35 % |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Rockwell hardness | ASTM D785 | 85 | |
R-Scale | ASTM D785 | 122 |
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
refractive index | ASTM D542 | 1.600 | |
transmissivity | ASTM D1003 | 85.0 % | |
Haze ratio | ASTM D1003 | 1.0 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2/1 | 2150 MPa | |
tensile strength | Yield | ASTM D638 | 65.0 MPa |
bending strength | ISO 178 | 66.0 MPa | |
ASTM D790 | 95.0 MPa | ||
Tensile modulus | ASTM D638 | 2100 MPa | |
Tensile strain | Break | ISO 527-2/50 | 85 % |
Flexural modulus | ASTM D790 | 2200 MPa | |
ISO 178 | 2120 MPa | ||
tensile strength | Yield | ISO 527-2/50 | 65.0 MPa |
Break | ASTM D638 | 70.0 MPa | |
Break | ISO 527-2/50 | 60.0 MPa | |
elongation | Yield | ASTM D638 | 7.0 % |
Tensile strain | Yield | ISO 527-2/50 | 7.0 % |
elongation | Break | ASTM D638 | >110 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | 13 kJ/m² | |
ISO 179/1eA | 57 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
ISO 179/1eU | NoBreak | ||
Impact strength of cantilever beam gap | ASTM D256 | 600 J/m | |
ISO 180/1A | 11 kJ/m² | ||
ISO 180/1A | 53 kJ/m² | ||
ASTM D4812 | NoBreak | ||
Suspended wall beam without notch impact strength | ISO 180/1U | NoBreak | |
ISO 180/1U | NoBreak | ||
Dart impact | ASTM D3763 | 120 J | |
ASTM D3029 | 149 J | ||
Impact strength of cantilever beam gap | ASTM D1822 | 577 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dissipation Factor | ASTM D150 | 0.024 | |
Volume resistivity | ASTM D257 | >2.6E+17 ohms·cm | |
dielectric strength | ASTM D149 | 20 kV/mm | |
dielectric constant | ASTM D150 | 3.15 | |
ASTM D150 | 3.00 | ||
Dissipation Factor | ASTM D150 | 1.2E-03 | |
ASTM D150 | 1.2E-03 | ||
dielectric constant | ASTM D150 | 3.15 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 142 °C | |
ISO 75-2/Af | 125 °C | ||
vicat | ASTM D152511 | 160 °C | |
ISO 306/B50 | 154 °C | ||
thermal conductivity | ASTMC177 | 0.21 W/m/K | |
vicat | ISO 306/B120 | 155 °C | |
Linear coefficient of thermal expansion | ASTME831 | 6E-05 cm/cm/°C | |
ISO 11359-2 | 6E-05 cm/cm/°C | ||
ASTME831 | 8E-05 cm/cm/°C | ||
ISO 11359-2 | 6E-05 cm/cm/°C | ||
specific heat | ASTMC351 | 1250 J/kg/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App