PC/ABS C2950HF-111 SABIC INNOVATIVE NANSHA
51
Form:Granules | Grade:Injection grade
Properties:
Flame retardantHigh mobilityHigh impact resistanceHigh temperature resistanheat-resisting
Typical Applications:
Electrical fieldElectronic fieldHousehold appliancesHousehold appliancesAutomotive sector
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical field | Electronic field | Household appliances | Household appliances | Automotive sector |
| Properties: | Flame retardant | High mobility | High impact resistance | High temperature resistan | heat-resisting |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Dart impact | 23°C,EnergyatPeakLoad | ASTM D3763 | 54.2 | J |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.76mm | UL 94 | V-2 | |
| 1.5mm | UL 94 | V-0 | ||
| 2.5mm | UL 94 | 5VB | ||
| 3.4mm | UL 94 | 5VA | ||
| Extreme Oxygen Index | ASTM D2863 | 30 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | Yield,100mmSpan | ASTM D790 | 96.5 | Mpa |
| tensile strength | Yield | ASTM D638 | 64.1 | Mpa |
| elongation | Yield | ASTM D638 | 5.0 | % |
| Break | ASTM D638 | 40 | % | |
| Bending modulus | 100mmSpan | ASTM D790 | 2590 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed,6.40mm | ASTM D648 | 102 | °C |
| 1.8MPa,Unannealed,3.20mm | ASTM D648 | 87.8 | °C | |
| 1.8MPa,Unannealed,6.40mm | ASTM D648 | 93.3 | °C | |
| Vicat softening temperature | ASTM D15254 | 113 | °C | |
| Linear coefficient of thermal expansion | MD:-30to30°C | ASTM D696 | 7.2E-05 | cm/cm/°C |
| TD:-30to30°C | ASTM D696 | 7.2E-05 | cm/cm/°C | |
| thermal conductivity | ASTMC177 | 0.20 | W/m/K | |
| RTI Elec | UL 746 | 85.0 | °C | |
| RTI Imp | UL 746 | 85.0 | °C | |
| RTI Str | UL 746 | 85.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 260°C/2.16kg | ASTM D1238 | 22 | g/10min |
| Shrinkage rate | MD:3.20mm | Internal Method | 0.40-0.60 | % |
| TD:3.20mm | Internal Method | 0.40-0.60 | % | |
| Water absorption rate | 24hr | ASTM D570 | 0.10 | % |
| Equilibrium,23°C | ASTM D570 | 0.40 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 50Hz | ASTM D150 | 5.2E-03 | |
| 60Hz | ASTM D150 | 5.2E-03 | ||
| 1MHz | ASTM D150 | 7.1E-03 | ||
| Arc resistance | ASTM D495 | PLC6 | ||
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 2 | |
| High arc combustion index | HAI | UL 746 | PLC 0 | |
| High voltage arc tracing rate | HVTR | UL 746 | PLC 3 | |
| Hot wire ignition | HWI | UL 746 | PLC 2 | |
| Surface resistivity | ASTM D257 | >1.0E+16 | ohms | |
| Volume resistivity | ASTM D257 | 1.6E+17 | ohms·cm | |
| Dielectric strength | 3.20mm,inOil | ASTM D149 | 24 | KV/mm |
| Dielectric constant | 50Hz | ASTM D150 | 2.80 | |
| 60Hz | ASTM D150 | 2.80 | ||
| 1MHz | ASTM D150 | 2.70 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 121 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.