Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTMD570 | 0.13 % |
intrinsic viscosity | | 内部方法 | 0.70 |
intrinsic viscosity | | 内部方法 | 0.75 |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ASTM D785 | 106 |
Rockwell hardness | | ISO 2039-2 | 109 |
optical performance | Test Condition | Test Method | Test Result |
---|
gloss | | ASTM D2457 | 108 |
transmissivity | | ASTM D1003 | 89.0 % |
transmissivity | | ASTM D1003 | 91.0 % |
transparency | | ASTM D1746 | 85.0 |
Haze ratio | | ASTM D1003 | 0.80 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam without notch impact strength | | ASTM D4812 | 无断裂 |
Suspended wall beam without notch impact strength | | ASTM D4812 | 无断裂 |
Suspended wall beam without notch impact strength | | ASTM D4812 | 无断裂 |
Suspended wall beam without notch impact strength | | ASTM D4812 | 无断裂 |
Suspended wall beam without notch impact strength | | ISO 180/1U | 无断裂 |
Suspended wall beam without notch impact strength | | ISO 180/1U | 无断裂 |
Suspended wall beam without notch impact strength | | ISO 180/1U | 无断裂 |
Suspended wall beam without notch impact strength | | ISO 180/1U | 无断裂 |
Dart impact | | ASTM D3763 | 41.0 J |
Dart impact | | ASTM D3763 | 50.0 J |
Dart impact | | ASTM D3763 | 28.0 J |
Dart impact | | ASTM D3763 | 33.0 J |
Dart impact | | ISO 6603-2 | 35.0 J |
Dart impact | | ISO 6603-2 | 36.0 J |
Dart impact | | ISO 6603-2 | 40.0 J |
Dart impact | | ISO 6603-2 | 44.0 J |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTMD638 | 2100 Mpa |
tensile strength | | ASTMD638 | 50.0 Mpa |
tensile strength | | ASTMD638 | 28.0 Mpa |
elongation | | ASTM D638 | 130 % |
elongation | | ISO 527-2 | 100 % |
Flexural modulus | | ASTM D790 | 2100 Mpa |
Flexural modulus | | ISO 178 | 2000 Mpa |
bending strength | | ISO 178 | 68.0 Mpa |
bending strength | | ASTM D790 | 70.0 Mpa |
tear strength | | - | 93 N |
tear strength | | - | 93 N |
film | Test Condition | Test Method | Test Result |
---|
Tear resistance of pants | | ISO 6383-1 | 36.0 N/mm |
OTr | | ASTM D3985 | 10 cm³·mm/m²/atm/24hr |
Water Vapor Transmission Rate | | ASTMF1249 | 7.0 g/m²/24hr |
Carbon dioxide transmittance | | ASTM D1434 | 49 cm³·mm/m²/atm/24hr |
tear strength | | ASTM D1938 | 36 kN/m |
tear strength | | ASTM D1938 | 36 kN/m |
tensile strength | | ASTM D882 | 55.0 Mpa |
elongation | | ASTM D882 | 4.0 % |
elongation | | ASTM D882 | 4.0 % |
elongation | | ASTM D882 | 400 % |
elongation | | ASTM D882 | 400 % |
Dart impact | | ASTM D1709A | 500 g |
Dart impact | | ASTM D1709A | 400 g |
Elmendorf tear strength | | ASTM D1922 | 1400 g |
Elmendorf tear strength | | ASTM D1922 | 1700 g |
Tear resistance of pants | | ISO 6383-1 | 36.0 N/mm |
film thickness | | | 250 µm |
Secant modulus | | ASTM D882 | 1900 Mpa |
Secant modulus | | ASTM D882 | 1900 Mpa |
tensile strength | | ASTM D882 | 52.0 Mpa |
tensile strength | | ASTM D882 | 52.0 Mpa |
tensile strength | | ASTM D882 | 59.0 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | ASTM D150 | 2.60 |
dielectric constant | | ASTM D150 | 2.40 |
Dissipation Factor | | ASTM D150 | 5E-03 |
Dissipation Factor | | ASTM D150 | 0.020 |
arc resistance | | ASTM D495 | 158 sec |
Surface Resistivity | | ASTM D257 | 1E+16 ohms |
Volume resistivity | | ASTM D257 | 1E+15 ohms·cm |
dielectric strength | | ASTM D149 | 16 KV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 70.0 °C |
Heat distortion temperature | | ASTM D648 | 64.0 °C |
Glass Transition Temperature | | DSC | 80.0 °C |
vicat | | ASTM D1525 | 85.0 °C |
Linear coefficient of thermal expansion | | ASTM D696 | 5.1E-05 cm/cm/°C |
specific heat | | DSC | 1300 J/kg/°C |
specific heat | | DSC | 1760 J/kg/°C |
specific heat | | DSC | 1880 J/kg/°C |
specific heat | | DSC | 1970 J/kg/°C |
specific heat | | DSC | 2050 J/kg/°C |
thermal conductivity | | ASTMC177 | 0.21 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.