PEEK A2000 BASF GERMANY

51

Form:Granules | Grade:Food grade

Product Description
Certificates(0)
Datasheet

Product Description

Certificates

No Data...

Technical Data Sheet

mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact StrengthASTM D256/ISO 1792.5kg·cm/cm(J/M)ft·lb/in
Charpy Notched Impact StrengthASTM D256/ISO 1794kg·cm/cm(J/M)ft·lb/in
Charpy Notched Impact StrengthASTM D256/ISO 1795kg·cm/cm(J/M)ft·lb/in
Impact strength of cantilever beam gapASTM D256/ISO 1793.5kg·cm/cm(J/M)ft·lb/in
Impact strength of cantilever beam gapASTM D256/ISO 1795kg·cm/cm(J/M)ft·lb/in
Impact strength of cantilever beam gapASTM D256/ISO 1793.8kg·cm/cm(J/M)ft·lb/in
Impact strength of cantilever beam gapASTM D256/ISO 17910kg·cm/cm(J/M)ft·lb/in
Elongation at BreakASTM D638/ISO 52720%
Elongation at BreakASTM D638/ISO 52720%
Tensile modulusASTM D638/ISO 5274400kg/cm²(MPa)[Lb/in²]
tensile strengthASTM D638/ISO 52760kg/cm²(MPa)[Lb/in²]
elongationASTM D638/ISO 5275%
Rockwell hardnessASTM D785M105
Bending modulusASTM D790/ISO 17875kg/cm²(MPa)[Lb/in²]
bending strengthASTM D790/ISO 178110kg/cm²(MPa)[Lb/in²]
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Combustibility (rate)UL 940
Hot deformation temperatureHDTASTM D648/ISO 75320℃(℉)
Hot deformation temperatureHDTASTM D648/ISO 75315℃(℉)
Melting temperature340℃(℉)
Vicat softening temperatureASTM D1525/ISO R3061℃(℉)
Linear coefficient of thermal expansionASTM D696/ISO 113590.8mm/mm.℃
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityASTM D792/ISO 11831.31
Shrinkage rateASTM D9555%
melt mass-flow rateASTM D1238/ISO 113333g/10min
melt mass-flow rateASTM D1238/ISO 11333g/10min
Water absorption rateASTM D570/ISO 620.06%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityASTM D257/IEC 60093>10Ω
Dielectric constantASTM D150/IEC 602503.2/3.2
Dielectric constantASTM D150/IEC 602503.2/3.6
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.