PBT VAMPTER 4554 V0 60 F20 VAMP TECH ITALY
Properties:
Filler glass mineral 45% filler by weight
Typical Applications:
Electrical and electronic application fields
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical and electronic application fields |
| Properties: | Filler | glass mineral | 45% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Suspended wall beam without notch impact strength | ISO 180 | 40 | kJ/m² | |
| Impact strength of cantilever beam gap | ISO 180/A | 7.0 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Burning wire flammability index | 1.0to2.0mm | IEC 60695-2-12 | 960 | °C |
| UL flame retardant rating | 3.2mm | UL 94 | V-0 | |
| 1.6mm | UL 94 | V-0 | ||
| 0.8mm | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| elongation | Break | ASTM D638 | 2.0 | % |
| tensile strength | Yield | ASTM D638 | 75.0 | MPa |
| Tensile modulus | ASTM D638 | 8000 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI | UL 746 | 135 | °C | |
| RTI Imp | UL 746 | 135 | °C | |
| RTI Elec | UL 746 | 135 | °C | |
| Vicat softening temperature | ASTM D15253 | 205 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648A | 205 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Saturation | ASTM D570 | 0.050 | % |
| Shrinkage rate | TD | ASTM D955 | 0.70 | % |
| MD | ASTM D955 | 0.40 | % | |
| density | ASTM D792 | 1.67 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.