Technical Data Sheet
thermal performance | Test Condition | Test Method | Test Result |
---|
Heat Deflection Temperature | 1.8MPa,未退火,6.40mm | ASTM D648 | 245 °C |
Heat Deflection Temperature | 1.8MPa,Unannealed,4.00mm | ISO 75-2/A | 245 °C |
optical performance | Test Condition | Test Method | Test Result |
---|
Yellowness Index | 3.20mm | ASTM D1925 | 3.0 YI |
Yellowness Index | -- | ASTM D1925 | 3.0 YI |
Physical properties | Test Condition | Test Method | Test Result |
---|
melt mass-flow rate | 300°C/2.16kg | ASTM D1238 | 60 g/10min |
melt mass-flow rate | 300°C/2.16kg | ISO 1133 | 60 g/10min |
density | | ASTM D792 | 1.53 g/cm³ |
density | | ISO 1183 | 1.53 g/cm³ |
mechanical properties | Test Condition | Test Method | Test Result |
---|
bending strength | | ASTM D790 | 94.0 MPa |
bending strength | | ISO 178 | 88.0 MPa |
tensile strength | Yield | ASTM D638 | 66.0 MPa |
tensile strength | Yield | ISO 527-2/5 | 58.0 MPa |
elongation | Break | ASTM D638 | 2.0 % |
Tensile strain | Break | ISO 527-2/5 | 2.0 % |
flexural modulus | | ASTM D790 | 5500 MPa |
flexural modulus | | ISO 178 | 5400 MPa |
impact performance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 2.0 kJ/m² |
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 25 kJ/m² |
Impact strength of cantilever beam gap | 23°C,3.18mm | ASTM D256 | 29 J/m |
Impact strength of cantilever beam gap | 23°C,6.35mm | ASTM D256 | 29 J/m |
Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 2.0 kJ/m² |
Impact strength of cantilever beam gap | 23°C,3.18mm | ASTM D256 | 300 J/m |
Impact strength of cantilever beam gap | 23°C,6.35mm | ASTM D256 | 290 J/m |
Suspended wall beam without notch impact strength | -5°C | ISO 180/1U | 30 kJ/m² |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.