Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.42 g/cm³ |
Water absorption rate | | ASTM D570 | 0.060 % |
Water absorption rate | Saturation | ASTM D570 | 0.35 % |
hardness | Test Condition | Test Method | Test Result |
---|
Shore hardness | | ASTM D2240 | 84 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTM D638 | 3170 MPa |
tensile strength | Yield | ASTM D638 | 79.3 MPa |
elongation | Break | ASTM D638 | 15 % |
Flexural modulus | | ASTM D790 | 3450 MPa |
bending strength | | ASTM D790 | 138 MPa |
coefficient of friction | Itself - Dynamic | ASTM D1894 | 0.10 |
coefficient of friction | Itself - Static | ASTM D1894 | 0.10 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 43 J/m |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 171 °C |
Glass Transition Temperature | | ASTME1356 | 143 °C |
melting temperature | | DSC | 343 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.