Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
| | ISO1133 | 31 g/10min |
| | ISO294-4 | 0.4-0.7 % |
Melt volume flow rate | | ISO1133 | 31.0 cm3/10min |
Shrinkage rate | | ISO294-4 | 0.40to0.70 % |
hardness | Test Condition | Test Method | Test Result |
---|
| | ISO2039-1 | 110 Mpa |
Other performance | Test Condition | Test Method | Test Result |
---|
Melting temperature | | ISO294 | 240 °C |
injection speed | | ISO294 | 240 mm/sec |
burning rate | | ISO3795 | 60 mm/min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ISO527-2 | 46 Mpa |
elongation at break | | ISO527-2 | 2.6 % |
elongation at break | | ISO527-2 | >=15 % |
Tensile modulus | | ISO527-2 | 2400 Mpa |
bending strength | | ISO178 | 70 Mpa |
Flexural modulus | | ISO178 | 2400 Mpa |
Charpy Notched Impact Strength | | ISO179/1eA | 15 kJ/m² |
Charpy Notched Impact Strength | | ISO179/1eA | 7 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 110 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 90 kJ/m² |
Impact strength of cantilever beam gap | | ISO180/1A | 15 kJ/m² |
Impact strength of cantilever beam gap | | ISO180/1A | 7 kJ/m² |
Tensile modulus | | ISO527-2 | 2400 Mpa |
Tensile stress | | ISO527-2 | 46.0 Mpa |
Tensile strain | | ISO527-2 | 2.6 % |
Tensile strain | | ISO527-2 | >15 % |
Flexural modulus | | ISO178 | 2400 Mpa |
Bending stress | | ISO178 | 70.0 Mpa |
| | ISO2039-1 | 105 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO179 | 90 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179 | 110 kJ/m² |
Flame retardant performance | Test Condition | Test Method | Test Result |
---|
GWIT | | IEC60695-2-12 | 700 °C |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | IEC60250 | 2.9 1MHz |
dielectric constant | | IEC60250 | 3 100HZ |
Dissipation Factor | | IEC60250 | 0.05 |
Dissipation Factor | | IEC60250 | 0.09 |
Dissipation Factor | | IEC60112 | 600 V |
| | IEC60093 | 1E+13 Ω.cm |
Surface Resistivity | | IEC60093 | 1E+15 Ω.cm |
Dielectric Strength | | IEC60243-1 | 35 KV/mm |
Surface Resistivity | | IEC60093 | >1.0E+15 ohms |
Volume resistivity | | IEC60093 | >1.0E+15 ohms·cm |
Electrical strength | | IEC60243-1 | 35 KV/mm |
| | IEC60250 | 3.00 |
| | IEC60250 | 2.90 |
Dissipation Factor | | IEC60250 | 5E-03 |
Dissipation Factor | | IEC60250 | 9E-03 |
CTI | | IEC60112 | 600 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO75-2/Bf | 98 °C |
| | ISO75-2/Af | 94 °C |
vicat | | ISO306/A50 | 99 °C |
| | ISO75-2/B | 98.0 °C |
| | ISO75-2/A | 94.0 °C |
vicat | | ISO306/B50 | 99.0 °C |
| | ISO11359-2 | 9E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.