Phenolic Durez® 153 (Injection) SBHPP
Typical Applications:
Electrical appliances electrical and electronic applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical appliances | electrical and electronic applications |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Suspended wall beam without notch impact strength | ASTM D256 | 16 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 3.0mm | UL 94 | V-0 | |
| 1.5mm | UL 94 | V-0 | ||
| 1.0mm | UL 94 | V-1 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ASTM D790 | 83.0 | MPa | |
| tensile strength | ASTM D638 | 62.0 | MPa | |
| Tensile modulus | ASTM D638 | 11000 | MPa | |
| compressive strength | ASTM D695 | 186 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | HDT | ASTM D648 | 177 | °C |
| RTI Elec | 3.0mm | UL 746 | 155 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium | ASTM D570 | 0.40 | % |
| Shrinkage rate | MD | ASTM D6289 | 1.1 | % |
| Apparent density | ASTM D1895 | 0.60 | g/cm³ | |
| density | ASTM D792 | 1.50 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 3 | ||
| Dissipation factor | 1MHz | ASTM D150 | 0.050 | |
| Dielectric constant | 1MHz | ASTM D150 | 5.10 | |
| Dielectric strength | --3 | ASTM D149 | 11 | kV/mm |
| --2 | ASTM D149 | 14 | kV/mm | |
| Volume resistivity | ASTM D257 | 1E+12 | ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.