Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Melt volume flow rate | | ISO1133 | 11.0 cm3/10min |
hardness | Test Condition | Test Method | Test Result |
---|
Ball Indentation Hardness | | ISO2039-1 | 85.0 Mpa |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | IEC60695-11-10,-20 | HB |
UL flame retardant rating | | IEC60695-11-10,-20 | HB |
Burning wire flammability index | | IEC60695-2-12 | 650 °C |
Burning wire flammability index | | IEC60695-2-12 | 650 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2/1A/1 | 1700 Mpa |
Tensile stress | | ISO527-2/1A/50 | 39.0 Mpa |
Tensile strain | | ISO527-2/1A/50 | 3.4 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO179/1eU | NoBreak |
Impact strength of simply supported beam without notch | | ISO179/1eU | NoBreak |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat Deflection Temperature | | ISO75-2/Bf | 87.0 °C |
Heat Deflection Temperature | | ISO75-2/Af | 66.0 °C |
vicat | | ISO306/A50 | 204 °C |
vicat | | ISO306/B50 | 120 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.