Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
transmittance | | ASTM D-1003 | MF|93 % |
transmittance | | ASTM D-1003 | 93 % |
refractive index | | ASTM D-542 | MF|1.49 |
refractive index | | ASTM D-542 | 1.49 |
processability | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTM D-955 | MF|0.2-0.6 % |
Shrinkage rate | | ASTM D-955 | 0.2-0.6 % |
Basic performance | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTM D-570 | MF|0.3 % |
Water absorption rate | | ASTM D-570 | 0.3 % |
melt mass-flow rate | | ASTM D-1238 | MF|2.0 g/10min |
melt mass-flow rate | | ASTM D-1238 | 2.5 g/10min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ASTM D-785 | MF|100 M Scale |
Rockwell hardness | | ASTM D-785 | 95 M Scale |
elongation at break | | ASTM D-638 | MF|5 % |
elongation at break | | ASTM D-638 | 5 % |
Impact strength of cantilever beam gap | | ASTM D-255 | MF|1.7 kg·cm/cm |
Impact strength of cantilever beam gap | | ASTM D-255 | 1.6 kg·cm/cm |
tensile strength | | ASTM D-638 | MF|740 kg/cm2 |
tensile strength | | ASTM D-638 | 730 kg/cm2 |
compressive strength | | ASTM D-695 | MF|1100 kg/cm2 |
compressive strength | | ASTM D-695 | 1100 kg/cm2 |
Flexural modulus | | ASTM D-790 | MF|3.2×104 kg/cm2 |
Flexural modulus | | ASTM D-790 | 3.1×104 kg/cm2 |
bending strength | | ASTM D-790 | MF|1100 kg/cm2 |
bending strength | | ASTM D-790 | 1100 kg/cm2 |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | | 3.7 |
Volume resistivity | | JIS K-6911 | MF|>1016 |
Volume resistivity | | JIS K-6911 | >1016 |
Dielectric loss | | | MF|0.05 |
Dielectric loss | | | 0.05 |
Volume resistivity | | JIS K-6911 | MF|>1015 |
Volume resistivity | | JIS K-6911 | >1015 |
arc resistance | | JIS K-6911 | MF|没有痕迹 |
arc resistance | | JIS K-6911 | 没有痕迹 |
dielectric strength | | | MF|20 |
dielectric strength | | | 20 |
dielectric constant | | | MF|3.7 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
vicat | | ASTM D-1525 | MF|116 °C |
vicat | | ASTM D-1525 | 107 °C |
thermal conductivity | | ASTM C-177 | MF|5×10-4 Cal/s/cm/℃ |
thermal conductivity | | ASTM C-177 | 5×10-4 Cal/s/cm/℃ |
specific heat | | | MF|0.35 cal/g/℃ |
specific heat | | | 0.35 cal/g/℃ |
Linear coefficient of thermal expansion | | ASTM D-696 | MF|6×10-5 cm/cm/℃ |
Linear coefficient of thermal expansion | | ASTM D-696 | 6×10-5 cm/cm/℃ |
Heat distortion temperature | | ASTM D-648 | MF|102 °C |
Heat distortion temperature | | ASTM D-648 | 92 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.