Share
Add to compare

PC/ABS GN-5001TF LG CHEM KOREA

48

Form:Granules | Grade:Injection grade

Properties:
Flame retardantheat-resisting
Typical Applications:
household electrical appliancesElectrical applications
Product Description
Certificates(1)
Datasheet

Product Description

Typical Applications:household electrical appliances | Electrical applications
Properties:Flame retardant | heat-resisting

Certificates

UL
UL

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CISO 179NoBreak
Impact strength of cantilever beam gap23°CISO 18013kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating1.2mmUL 94V-0
UL flame retardant rating1.5mmUL 945VB
UL flame retardant rating2.5mmUL 945VA
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusISO 527-2/12500Mpa
tensile strengthYieldISO 527-2/5062.0Mpa
Tensile strainBreakISO 527-2/50>20%
Bending modulusISO 1782600Mpa
bending strengthISO 17893.0Mpa
Impact strength of cantilever beam gapASTM D256/ISO 17940kg·cm/cm(J/M)ft·lb/in
Elongation at BreakASTM D638/ISO 52750%
tensile strengthASTM D638/ISO 527560kg/cm²(MPa)[Lb/in²]
Bending modulusASTM D790/ISO 17825000kg/cm²(MPa)[Lb/in²]
bending strengthASTM D790/ISO 178820kg/cm²(MPa)[Lb/in²]
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B91.0°C
Vicat softening temperatureISO 306/B5099.0°C
Combustibility (rate)UL 94V-0(1.5mm)
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
melt mass-flow rate250°C/2.16kgISO 113320g/10min
Shrinkage rateMDInternal Method0.40-0.60%
densityASTM D792/ISO 11831.18
Shrinkage rateASTM D9550.4-0.6%
melt mass-flow rateASTM D1238/ISO 113320g/10min
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.