PC 3760/13701 MITSUBISHI ENGINEERING JAPAN
46
Form:Granules | Grade:Injection grade
Properties:
Thermal stabilityUV resistance
Typical Applications:
Automotive Applicationselectrical equipment
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive Applications | electrical equipment |
| Properties: | Thermal stability | UV resistance |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Multi axis Instrumented Impact Energy | 23°C2 | Internal Method | 25.0 | J |
| 23°C | ISO 6603-2 | 40.0 | J | |
| -20°C2 | Internal Method | 25.0 | J | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | NoBreak | |
| -30°C | ISO 179/1eU | NoBreak | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.5mm | IEC 60695-11-10,-20 | V-1 | |
| 0.60mm | IEC 60695-11-10,-20 | V-1 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ISO 178 | 90.0 | Mpa | |
| Bending modulus | ISO 178 | 2400 | Mpa | |
| Nominal tensile fracture strain | ISO 527-2 | >50 | % | |
| Tensile strain | Yield | ISO 527-2 | 5.0 | % |
| tensile strength | Yield | ISO 527-2 | 60.0 | Mpa |
| Tensile modulus | ISO 527-2 | 2500 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 103 | °C |
| Vicat softening temperature | ISO 306/B50 | 110 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.35 | % |
| Shrinkage rate | MD | ISO 294-4 | 0.60 | % |
| Melt Volume Flow Rate (MVR) | 260°C/5.0kg | ISO 1133 | 28.0 | cm3/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 1.00GHz | IEC 60250 | 5E-03 | |
| Dielectric constant | 1.00GHz | IEC 60250 | 3.00 | |
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.