PP Polifor® 5210/V2 NATURALE SO.F.TER ITALY
Properties:
Filler mineral filler 10% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | mineral filler | 10% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 0°C | ASTM D256 | 20 | J/m |
| 23°C | ASTM D256 | 30 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.8mm | UL 94 | V-2 | |
| 1.6mm | UL 94 | V-2 | ||
| 3.2mm | UL 94 | V-2 | ||
| Hot filament ignition temperature | IEC 60695-2-13 | 960 | °C | |
| Extreme Oxygen Index | ASTM D2863 | 23 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield | ASTM D638 | 30.0 | MPa |
| elongation | Break | ASTM D638 | 10 | % |
| Bending modulus | ASTM D790 | 1700 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ASTM D15252 | 93.0 | °C | |
| Ball Pressure Test | 125°C | IEC 335 | Pass | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 65.0 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.01 | g/cm³ | |
| melt mass-flow rate | 230°C/2.16kg | ASTM D1238 | 12 | g/10min |
| Shrinkage rate | Internal Method | 1.4 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Needle flame test | IEC 60695-11-5 | Pass | ||
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.