Polyester Alloy Politen® G7035 Iten Industries
Properties:
Filler glass fiber reinforced material
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D256 | 110to210 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ASTM D790 | 110to138 | MPa | |
| tensile strength | ASTM D638 | 55.2to68.9 | MPa | |
| compressive strength | ASTM D695 | 152to179 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Elec | UL 746 | 130 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | >260 | °C |
| RTI | UL 746 | 130 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 24hr | ASTM D570 | 0.10 | % |
| Shrinkage rate | MD | ASTM D955 | 0.25to0.40 | % |
| density | ASTM D792 | 1.81 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 0 | |
| Arc resistance | ASTM D495 | 146 | sec | |
| Dielectric strength | ASTM D149 | 14 | kV/mm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Babbitt hardness | 35to45 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.