Share
Add to Compare

PC 3412ECR-739 SABIC INNOVATIVE NANSHA

323

Form:Granules | Grade:Enhanced level

Properties:
Glass fiber reinforcedenhanceFlame retardantHigh rigidity
Typical Applications:
Plastic bagAutomotive External PartsIndustrial applicationsElectrical appliancesLighting applicationsMedical supplies
Product Description
Certificates(1)
Datasheet

Product Description

Typical Applications:Plastic bag | Automotive External Parts | Industrial applications | Electrical appliances | Lighting applications | Medical supplies
Properties:Glass fiber reinforced | enhance | Flame retardant | High rigidity

Certificates

UL
UL

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CISO 179/1eU40kJ/m²
Impact strength of cantilever beam gap-30°CISO 180/1A6.0kJ/m²
Impact strength of cantilever beam gap-30°CASTM D256110J/m
Impact strength of cantilever beam gap23°CASTM D256110J/m
Impact strength of cantilever beam gap23°CISO 180/1A7.0kJ/m²
Suspended wall beam without notch impact strength-30°CISO 180/1U35kJ/m²
Suspended wall beam without notch impact strength23°CISO 180/1U35kJ/m²
Dart impact23°C,TotalEnergyASTM D376320.0J
Charpy Notched Impact Strength23°CISO 179/1eA6.0kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU40kJ/m²
Charpy Notched Impact Strength-30°CISO 179/1eA5.0kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
Extreme Oxygen IndexISO 4589-240%
UL flame retardant rating1.5mmUL 94V-0
UL flame retardant rating3.0mmUL 945VA
Burning wire flammability index1.0mmIEC 60695-2-12960°C
Hot filament ignition temperature1.0mmIEC 60695-2-13825°C
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
tensile strengthBreakISO 527-2/590.0Mpa
tensile strengthBreakASTM D63887.0Mpa
tensile strengthYieldISO 527-2/595.0Mpa
tensile strengthYieldASTM D63890.0Mpa
Tensile modulusISO 527-2/16000Mpa
Tensile modulusASTM D6385500Mpa
Bending modulusISO 1785500Mpa
bending strengthISO 178140Mpa
elongationYieldASTM D6383.1%
Tensile strainYieldISO 527-2/52.8%
bending strengthYield,50.0mmSpanASTM D790156Mpa
Tensile strainBreakISO 527-2/53.2%
Bending modulus50.0mmSpanASTM D7905000Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
RTI ImpUL 746130°C
RTI ElecUL 746130°C
Linear coefficient of thermal expansionTD:23to80°CISO 11359-27E-05cm/cm/°C
Hot deformation temperature1.8MPa,Unannealed,64.0mmSpanISO 75-2/Af136°C
Linear coefficient of thermal expansionTD:-40to40°CASTME8317E-05cm/cm/°C
Linear coefficient of thermal expansionMD:23to80°CISO 11359-23E-05cm/cm/°C
Vicat softening temperature--ISO 306/B50145°C
Vicat softening temperatureASTM D152510147°C
RTI StrUL 746130°C
Linear coefficient of thermal expansionMD:-40to40°CASTME8313E-05cm/cm/°C
Ball Pressure Test125°CIEC 60695-10-2Pass
Vicat softening temperature--ISO 306/B120146°C
Hot deformation temperature0.45MPa,Unannealed,64.0mmSpanISO 75-2/Bf141°C
Hot deformation temperature1.8MPa,Unannealed,3.20mmASTM D648141°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Water absorption rateEquilibrium,23°C,50%RHISO 620.12%
Water absorption rateSaturation,23°CISO 620.29%
Shrinkage rateTD:3.20mmInternal Method0.20-0.50%
Shrinkage rateMD:3.20mmInternal Method0.20-0.50%
Melt Volume Flow Rate (MVR)300°C/1.2kgISO 11337.00cm3/10min
melt mass-flow rate300°C/1.2kgASTM D12387.0g/10min
densityISO 11831.36g/cm³
densityASTM D7921.30g/cm³
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityIEC 60093>1.0E+15ohms
Volume resistivityIEC 60093>1.0E+15ohms·cm
Relative permittivity50HzIEC 602503.30
Relative permittivity60HzIEC 602503.30
Relative permittivity1MHzIEC 602503.30
Dissipation factor50HzIEC 602500.020
Compared to the anti leakage trace indexCTIUL 746PLC 3
High arc combustion indexHAIUL 746PLC 3
High voltage arc tracing rateHVTRUL 746PLC 3
Hot wire ignitionHWIUL 746PLC 0
Dissipation factor60HzIEC 602500.020
Dissipation factor1MHzIEC 602500.010
Arc resistanceASTM D495PLC7
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Sourcing & Prices

Selling & Verification

Explore Materials

Price Index

+86 0755 27873515

Room 906, Global Digital Building, No. 9 Gaoxin Middle 3rd Road, Maling Community, Yuehai Subdistrict, Nanshan District, Shenzhen, Guangdong Province, China