Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Rockwell hardness | ASTM D785 | 93 | M-scale | |
| tensile strength | ASTM D638 | 900-1200 | kg/cm | |
| bending strength | ASTM D790 | 1400-1800 | kg/cm | |
| Bending modulus | ASTM D790 | ≥50000 | kg/cm | |
| Impact strength of cantilever beam gap | ASTM D256 | 5-8 | kg.cm/cm | |
| Elongation at Break | ASTM D638 | 2.5-4.5 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Flame resistance | UL 94 | V-0 | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 18.6kg/cm | ASTM D648 | 205 | °C |
| 4.6kg/cm | ASTM D648 | 220 | °C | |
| Water absorption rate | 24h | ASTM D570 | 0.03 | % |
| Melting temperature | DSC | 225 | °C | |
| Linear coefficient of thermal expansion | ASTM D696 | 4 | 10 | |
| Fiberglass content | CCP | 20 | % | |
| density | ASTM D792 | 1.50-1.56 | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Induced positive connection | ASTM D150 | 0.001 | 60Hz | |
| Volume resistivity | ASTM D257 | >10 | Ω | |
| Dielectric strength | ASTM D149 | >20 | KV/mm | |
| Dielectric constant | ASTM D150 | 4.5 | 60Hz | |
| Volume resistivity | ASTM D257 | >10 | Ω.cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.