PA12 L25W40X EMS-CHEMIE SWITZERLAND
70
Form:Granules | Grade:Injection grade
Properties:
High impact resistancehigh viscosity
Typical Applications:
Automotive sectorConsumer goods sectorPneumatic applicationsIndustrial applicationsHydraulic applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive sector | Consumer goods sector | Pneumatic applications | Industrial applications | Hydraulic applications |
| Properties: | High impact resistance | high viscosity |
Certificates
No Data...
Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Water absorption rate | 23℃/50%rh | DIN 53495 | 0.7 | % |
| 23℃/100%rh | DIN 53495 | 1.4 | % | |
| density | ISO 1183 | 1.02 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Elongation at Break | ASTM D412/ISO 527 | >50 | % | |
| Impact strength of cantilever beam gap | 0℃ | ISO 180/IC | 无断裂 | KJ/m |
| tensile strength | 50mm/min,Yield | ISO 527 | 25 | Mpa |
| Shore hardness | IOS 2039-1 | 30 | Mpa | |
| Elongation at Break | 50mm/min | ISO 527 | 200-300 | % |
| Impact strength of cantilever beam gap | 23℃ | ISO 180/IA | 无断裂 | kj/cm |
| elongation | ASTM D412/ISO 527 | 20 | % | |
| Tensile modulus | ASTM D412/ISO 527 | 360 | kg/cm²(MPa)[Lb/in²] | |
| tensile strength | 50mm/min,Break | ISO 527 | 40 | Mpa |
| Impact strength of cantilever beam gap | -30℃ | ISO 180/IA | 13 | kj/cm |
| Tensile modulus | ISO 527 | 360 | Mpa | |
| Impact strength of cantilever beam gap | 23℃ | ISO 180/IC | 无断裂 | KJ/m |
| elongation at yield | 50mm/min | ISO 527 | 30 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 3146-C | 173 | °C | |
| Hot deformation temperature | 1.82MPa | ISO 75 | 44 | °C |
| 0.46MPa | ISO 75 | 95 | °C | |
| Melting temperature | 173 | ℃(℉) | ||
| Hot deformation temperature | HDT | ASTM D648/ISO 75 | 45 | ℃(℉) |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | ASTM D570/ISO 62 | 1.4 | % | |
| density | ASTM D792/ISO 1183 | 1.02 | kg·cm/cm(J/M)ft·lb/in | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | ASTM D257/IEC 60093 | 10^11 | Ω |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.