PFA MFA F1530 SOLVAY FRANCE
28
Form:Granules | Grade:Injection grade
Properties:
Flame retardantHigh cracking (stress craLow traffic
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Flame retardant | High cracking (stress cra | Low traffic |
Certificates
No Data...
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| UL flame retardant rating | UL 94 | V-0 | ||
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 372℃/5.0kg | ASTM D-1238 | 4-8 | g/10min |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | 23℃,Break | ASTM D-1708 | >28 | MPa |
| Elongation at Break | 23℃ | ASTM D-1708 | >300 | % |
| Charpy Notched Impact Strength | ASTM D-3307 | No Break | ||
| Shore hardness | Shore D | ASTM D-2240 | 55-60 | |
| Tensile modulus | 23℃ | ASTM D-1708 | 400-500 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ASTM D-3307 | 265-275 | ℃ | |
| Crystallization peak temperature | ASTM D-3418 | 255-265 | ℃ | |
| Linear coefficient of thermal expansion | Flow | ASTM D-696 | 0.00012-0.0002 | cm/cm/℃ |
| specific heat | 23℃ | DSC | 900-1100 | J/kg/℃ |
| Crystallization peak temperature | DSC | 16-24 | J/g | |
| Melting heat | DSC | 16-24 | J/g | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | ASTM D-257 | >1E+17 | ohms | |
| Volume resistivity | ASTM D-257 | >1E+17 | ohm·cm | |
| Dielectric strength | 1mm | ASTM D-149 | 35-40 | kV/mm |
| Dielectric constant | 23℃,50Hz | ASTM D-150 | 2 | |
| 23℃,100000Hz | ASTM D-150 | 2 | ||
| Dissipation factor | 23℃,50Hz | ASTM D-150 | 0.0005 | |
| 23℃,100000Hz | ASTM D-150 | 0.0005 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.