Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | | 8.0 % |
Water absorption rate | | | 2.8 % |
density | | | 1.14 g/cm³ |
Shrinkage rate | | | 1.4to1.5 % |
Water absorption rate | | | 1.5 % |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | | PX-2 |
Trekking Services | | | 15200 mm |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | Yield | | 70.0 MPa |
Tensile strain | Break | | 30 % |
Flexural modulus | | | 2700 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | | 6.5 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | | 1E+15 ohms |
Volume resistivity | | | 1E+15 ohms·cm |
dielectric strength | | | 22 kV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | | 80.0 °C |
melting temperature | | | 260 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.