PSU UDEL®  P-1700 NT11 SOLVAY USA

62
  • Properties:
    dimensional stability
    Electron beam disinfectio
    Radiopable
    Radiation disinfection
    Pressure cooker disinfect
    Good disinfection perform
    Ethylene oxide disinfecti
    Anti gamma radiation
    Chemical resistance
    Alkali resistant
    Alcohol resistance
    heat-resisting
    Acid resistance
    Resistance to hydrocarbon
    Detergent resistant
    Steam resistant
    Thermal disinfection
    High toughness
    Biocompatibility
    Food contact compliance
    Hydrolysis resistance
    Disinfect with steam
    Excellent appearance
  • Usages:
    Electrical field
    Electronic field
    Electrical components
    Electrical appliances
    valve
    Valve components
    Industrial components
    Pipeline components
    Pipeline components
    Home appliance components
    Automotive sector
    Food service sector
    Surgical instruments
    Microwave cooker
    Dental application field
    Medical supplies
    Nursing supplies
    Medical devices
    Medical devices

Technical Data Sheet

物理性能Test ConditionTest MethodTest Result
密度ASTMD7921.24 g/cm³
熔体质量流动速率343°C/2.16kgASTMD12386.5 g/10min
收缩率MDASTMD9550.70 %
吸水率24hrASTMD5700.30 %
热性能Test ConditionTest MethodTest Result
热变形温度1.8MPa,未退火ASTMD648174 °C
线性热膨胀系数MDASTMD6965.6E-05 cm/cm/°C
可燃性Test ConditionTest MethodTest Result
UL阻燃等级1.5mm,ALLUL94HB
UL阻燃等级4.5mm,NCUL94V-0
灼热丝易燃指数0.8mmIEC60695-2-12850 °C
灼热丝易燃指数1.6to6.0mmIEC60695-2-12960 °C
热灯丝点火温度0.8mmIEC60695-2-13875 °C
热灯丝点火温度1.6to6.0mmIEC60695-2-13850 °C
机械性能Test ConditionTest MethodTest Result
拉伸模量ASTMD6382480 Mpa
抗张强度ASTMD63870.3 Mpa
伸长率断裂ASTMD63850to100 %
弯曲模量ASTMD7902690 Mpa
弯曲强度ASTMD790106 Mpa
电气性能Test ConditionTest MethodTest Result
耗散因数1MHzASTMD1506E-03
体积电阻率ASTMD2573E+16 ohms·cm
介电强度ASTMD14917 KV/mm
介电常数60HzASTMD1503.03
介电常数1kHzASTMD1503.04
介电常数1MHzASTMD1503.02
耗散因数60HzASTMD1507E-04
耗散因数1kHzASTMD1501E-03
冲击性能Test ConditionTest MethodTest Result
悬壁梁缺口冲击强度ASTMD25669 J/m
拉伸冲击强度ASTMD1822420 kJ/m²
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.