PPE XYRON™ G702H-ASY3306 ASAHI JAPAN
33
- Properties:High temperature resistanFlame retardantFiller: Glass fiber reinf20% filler by weight
- Usages:Automotive interior partshousehold electrical appliances
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179 | 11 kJ/m² |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 1.5mm | UL 94 | HB |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| bending strength | 23°C | ISO 178 | 162 Mpa |
| Bending modulus | 23°C | ISO 178 | 5870 Mpa |
| Tensile strain | Break,23°C | ISO 527-2 | 2.0 % |
| tensile strength | Yield,23°C | ISO 527-2 | 102 Mpa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 140 °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 139 °C | |
| Linear coefficient of thermal expansion | MD:-30to65°C | ISO 11359-2 | 5E-05 cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | 23°C,24hr | ISO 62 | 0.060 % |
| Shrinkage rate | 2.00mm | Internal Method | 0.25-0.50 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Dissipation factor | 1MHz | IEC 60250 | 1.1E-03 |
| 100Hz | IEC 60250 | 6E-04 | |
| Dielectric constant | 1MHz | IEC 60250 | 3.10 |
| 100Hz | IEC 60250 | 3.10 | |
| Dielectric strength | 2.00mm | IEC 60243-1 | 43 KV/mm |
| Volume resistivity | 23°C | IEC 60093 | 1E+16 ohms·cm |
| Surface resistivity | IEC 60093 | 1E+16 ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.