PA4T ForTii® F11 BK DSM HOLAND

143
  • Properties:
    Thermal stability
    Flame retardant
  • Usages:
    Electronic and electrical components

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Shrinkage rateISO 294-41.2 %
Shrinkage rateISO 294-40.30 %
Water absorption rateISO 621.6 %
flammabilityTest ConditionTest MethodTest Result
Flammability levelIEC 60695-11-10, -20V-0
Flammability levelIEC 60695-11-10, -20V-0
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-212000 Mpa
Tensile modulusISO 527-27500 Mpa
Tensile modulusISO 527-25000 Mpa
Tensile stressISO 527-2155 Mpa
Tensile stressISO 527-2100 Mpa
Tensile stressISO 527-270.0 Mpa
Tensile strainISO 527-22.0 %
Tensile strainISO 527-22.7 %
Tensile strainISO 527-23.7 %
Flexural modulusISO 17811500 Mpa
Bending stressISO 178245 Mpa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of simply supported beam without notchISO 179/1eU50 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivityIEC 60093> 1.0E+15 ohms·cm
dielectric strengthIEC 60243-133 KV/mm
IEC 602504.20
IEC 602503.90
IEC 602503.90
IEC 602503.90
CTIIEC 60112600 V
Thermal performanceTest ConditionTest MethodTest Result
ISO 75-2/A305 °C
Melting temperature 3ISO 11357-3325 °C
ISO 11359-21.5E-5 3.0E-5 cm/cm/°C
ISO 11359-23.5E-5 7.0E-5 cm/cm/°C
RTI ElecUL 746140 °C
Thermal Index - 5000 hrIEC 60216163 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top