PBT/PC V3900WX-BK1066 SABIC INNOVATIVE SHANGHAI
55
Form:Granules | Grade:Flame retardant grade
Properties:
High impactLow warpageDimensional stabilityHigh toughnessWeather resistance
Typical Applications:
Automotive sectorCharging stationElectronic and electrical enclosureLighting applicationsCommunication equipmentWire and cable
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive sector | Charging station | Electronic and electrical enclosure | Lighting applications | Communication equipment | Wire and cable |
| Properties: | High impact | Low warpage | Dimensional stability | High toughness | Weather resistance |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23℃ | ASTM D256 | 800 | J/m |
| 80*10*4,30℃ | ISO 180/1A | 8 | kJ/m² | |
| 30℃ | ASTM D256 | 110 | J/m | |
| Charpy Notched Impact Strength | V-notch,23℃ | ISO 179/1eA | 52 | kJ/m² |
| Impact strength of cantilever beam gap | 80*10*4,23℃ | ISO 180/1A | 45 | kJ/m² |
| Instrumented dart impact energy -40 ℃ (-40 ℉) total energy | ASTM D3763 | 50 | J | |
| Instrumented dart impact energy 23 ℃ (73 ℉) total energy | ASTM D3763 | 50 | J | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 1 mm/mi | ISO 527 | 2090 | Mpa |
| 5 mm/mi | ASTM D638 | 2200 | Mpa | |
| Bending modulus | 2 mm/m | ISO 178 | 2130 | Mpa |
| 1.3 mm/m | ASTM D790 | 2200 | Mpa | |
| bending strength | 2 mm/m,Yield | ISO 178 | 73 | Mpa |
| 1.3 mm,Yield | ASTM D790 | 80 | Mpa | |
| Elongation at Break | 50 mm/m | ISO 527 | 42 | |
| Type I, 50 | ASTM D638 | 50 | ||
| ASTM D638 | 250 | |||
| elongation | 50 mm/m,Yield | ISO 527 | 4 | |
| Type I, 50,Yield | ASTM D638 | 5 | ||
| tensile strength | Type I, 50,Break | ASTM D638 | 43 | Mpa |
| 50 mm/m,Break | ISO 527 | 40 | Mpa | |
| Yield | Internal | 48 | Mpa | |
| 50 mm/m,Yield | ISO 527 | 51 | Mpa | |
| Type I, 50,Yield | ASTM D638 | 53 | Mpa | |
| thermal properties | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | Rate B/50 | ASTM D1525 | 105 | °C |
| Rate B/5 | ISO 306 | 123 | °C | |
| Rate B/5 | ISO 306 | 121 | °C | |
| RTI Imp | UL 746B | 120 | °C | |
| Linear coefficient of thermal expansion | -40°C to 4,Flow | ISO 11359-2 | 88.4 E-6 | °C |
| -40°C to 4,Across Flow | ASTM E831 | 89.7 E-6 | °C | |
| RTI Elec | UL 746B | 120 | °C | |
| RTI Imp | UL 746B | 120 | °C | |
| Linear coefficient of thermal expansion | -40°C to 4,Flow | ASTM E831 | 88.4 E-6 | °C |
| -40°C to 4,Across Flow | ISO 11359-2 | 89.7 E-6 | °C | |
| Ball indentation temperature | Pass | IEC 60695-10-2 | 75 | °C |
| Pass | IEC 60695-10-2 | 125 | °C | |
| combustion performance | Test Condition | Test Method | Test Result | Test Unit |
| UL fire rating V | UL 94 | 1.5 | mm | |
| UL flame retardant rating | 5VA | UL 94 | 3 | mm |
| Glow wire combustion index (GWFI) | 1mm | IEC 60695-2-12 | 960 | passes at |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23°C / 50 | ISO 62 | 0.03 | |
| 23°C/sat | ISO 62 | 0.1 | ||
| Shrinkage rate | flow, 3.2 | Internal | 0.7-1 | |
| Melt Volume Flow Rate (MVR) | ISO 1133 | 11 | cm³/10 min | |
| melt mass-flow rate | ASTM D1238 | 35 | g/10min | |
| Electrical Property | Test Condition | Test Method | Test Result | Test Unit |
| Glow wire combustion index (GWFI) | 3mm | IEC 60695-2-12 | 960 | passes |
| Glow wire ignition temperature (GWIT) | 1.0mm | IEC 60695-2-13 | 825 | |
| 3.0mm | IEC 60695-2-13 | 725 | by VDE | |
| UV exposure, water exposure test, and immersion | UL 746C | F1 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.