PA66 VAMPAMID 66 3054 V0 VAMP TECH ITALY
0
- Properties:Fillerglass mineral30%filler by weight
- Usages:Electrical and electronic application fields
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792 | 1.59 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 | |
UL 94 | V-0 | ||
UL 94 | V-0 | ||
Burning wire flammability index | IEC 60695-2-12 | 960 °C | |
Hot filament ignition temperature | IEC 60695-2-13 | 775 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ASTM D638 | 7500 MPa | |
tensile strength | Yield | ASTM D638 | 100 MPa |
elongation | Break | ASTM D638 | 2.2 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ISO 180/A | 4.5 kJ/m² | |
Suspended wall beam without notch impact strength | ISO 180 | 35 kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648A | 215 °C | |
vicat | ASTM D15253 | 225 °C | |
RTI Elec | UL 746 | 140 °C | |
RTI Imp | UL 746 | 140 °C | |
RTI | UL 746 | 140 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.