PSU UDEL® P-3500 LCD MB7
82
- Properties:Hydrolysis resistanceChemical resistance
- Usages:Home appliance componentsIndustrial components
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
melt mass-flow rate | ASTMD1238 | 3.0to5.0 g/10min | |
Shrinkage rate | ASTMD955 | 0.70 % | |
Water absorption rate | ASTMD570 | 0.30 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ASTMD638 | 2480 Mpa | |
tensile strength | ASTMD638 | 70.3 Mpa | |
elongation | ASTMD638 | 50to100 % | |
Flexural modulus | ASTMD790 | 2690 Mpa | |
bending strength | ASTMD790 | 106 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile impact strength | ASTMD1822 | 420 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
dielectric constant | ASTMD150 | 3.04 | |
ASTMD150 | 3.02 | ||
Dissipation Factor | ASTMD150 | 7E-03 | |
ASTMD150 | 1E-03 | ||
ASTMD150 | 6E-03 | ||
Volume resistivity | ASTMD257 | 3E+16 ohms·cm | |
dielectric strength | ASTMD149 | 17 KV/mm | |
dielectric constant | ASTMD150 | 3.03 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTMD648 | 174 °C | |
ASTMD696 | 5.6E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.