Phenolic RESINOL® EPF 87120

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO11831.85到1.95 g/cm³
Apparent densityISO600.60到0.80 g/cm³
Shrinkage rateISO25770.30到0.50 %
Water absorption rateISO62<0.10 %
PostShrinkageISO2577<0.050 %
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94V-0
Burning wire flammability indexIEC60695-2-12960 °C
Hot filament ignition temperatureIEC60695-2-13960 °C
Supplementary InformationTest ConditionTest MethodTest Result
CompressionMoldingPressure>20.0 MPa
CompressionMoldingTemperature165到180 °C
Mechanical propertiesTest ConditionTest MethodTest Result
Flexural modulusInjectionISO17818000到22000 MPa
Bending stressCompression MoldedISO178150到180 MPa
Bending stressInjectionISO178220到240 MPa
compression stressISO604280到330 MPa
Tensile modulusCompression MoldedISO527-214000到18000 MPa
Tensile modulusInjectionISO527-216000到20000 MPa
Tensile stressISO527-280.0到100 MPa
Tensile stressInjectionISO527-2120到140 MPa
Flexural modulusCompression MoldedISO17816000到18000 MPa
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthCompression MoldedISO179/1eA4.0到6.0 kJ/m²
Charpy Notched Impact StrengthInjectionISO179/1eA5.0到7.0 kJ/m²
Impact strength of simply supported beam without notchCompression MoldedISO179/1eU8.0到10 kJ/m²
Impact strength of simply supported beam without notchInjectionISO179/1eU12到14 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC600931.0E+10到1.0E+11 ohms
Volume resistivityIEC600931.0E+12到1.0E+13 ohms·cm
dielectric strengthIEC60243-120到30 kV/mm
IEC602506.008.00
IEC602504.006.00
Dissipation FactorIEC602500.10到0.20
Dissipation FactorIEC602500.020到0.030
arc resistanceASTMD495PLC 4
CTIIEC60112>175 V
Thermal performanceTest ConditionTest MethodTest Result
ISO75-2/A>200 °C
ISO75-2/C160到180 °C
ISO11359-21.5E-5到2.0E-5 cm/cm/°C
thermal conductivityASTME14610.40到0.60 W/m/K
maximum service temperatureIEC60216230 °C
maximum service temperatureIEC60216150 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.