PC Makrolon® 3208
46
- Properties:High impact resistancehigh molecular weightDrinking water contact
- Usages:building materialsCastersTransportation equipment
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO 2577 | 0.60-0.80 % | |
Water absorption rate | ISO 62 | 0.30 % | |
Shrinkage rate | ISO 294-4 | 0.70 % | |
Water absorption rate | ISO 62 | 0.12 % | |
Shrinkage rate | ISO 294-4 | 0.75 % | |
Melt volume flow rate | ISO 1133 | 5.00 cm3/10min | |
Shrinkage rate | ISO 2577 | 0.60-0.80 % | |
melt mass-flow rate | ISO 1133 | 5.5 g/10min | |
density | ISO 1183 | 1.20 g/cm³ | |
Apparent density | ISO 60 | 0.66 g/cm³ |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
ball-indentation hardness | ISO 2039-1 | 111 Mpa |
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
transmissivity | ISO 13468-2 | 87.0 % | |
Haze ratio | ISO 14782 | <0.80 % | |
transmissivity | ISO 13468-2 | 89.0 % | |
ISO 13468-2 | 89.0 % | ||
ISO 13468-2 | 88.0 % | ||
refractive index | ISO 489 | 1.587 |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
FlashIgnitionTemperature | ASTM D1929 | 480 °C | |
SelfIgnitionTemperature | ASTM D1929 | 550 °C |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
Impact strength of cantilever beam gap | ISO 7391 | 75 kJ/m² | |
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
Impact strength of cantilever beam gap | ISO 7391 | 20 kJ/m² | |
Charpy Notched Impact Strength | ISO 7391 | 18 kJ/m² | |
ISO 7391 | 80 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
Multi axis Instrumented Peak Impact Force | ISO 6603-2 | 5800 N | |
ISO 6603-2 | 6700 N | ||
Multi axis Instrumented Impact Energy | ISO 6603-2 | 65.0 J | |
ISO 6603-2 | 75.0 J |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Bending Strain | ISO 178 | 7.2 % | |
bending strength | ISO 178 | 95.0 Mpa | |
Tensile strain | ISO 527-2/50 | 6.3 % | |
Flexural modulus | ISO 178 | 2350 Mpa | |
bending strength | ISO 178 | 72.0 Mpa | |
Tensile creep modulus | ISO 899-1 | 1900 Mpa | |
ISO 899-1 | 2200 Mpa | ||
Tensile strain | ISO 527-2/50 | 120 % | |
Nominal tensile fracture strain | ISO 527-2/50 | >50 % | |
tensile strength | ISO 527-2/50 | 75.0 Mpa | |
ISO 527-2/50 | 65.0 Mpa | ||
Tensile modulus | ISO 527-2/1 | 2350 Mpa |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ball-indentation hardness | IEC 60695-10-2 | Pass | |
vicat | ISO 306/B120 | 151 °C | |
Heat distortion temperature | ISO 75-2/A | 130 °C | |
vicat | ISO 306/B50 | 150 °C | |
Glass Transition Temperature | ISO 11357-2 | 150 °C | |
Heat distortion temperature | ISO 75-2/B | 142 °C | |
thermal conductivity | ISO 8302 | 0.20 W/m/K | |
Linear coefficient of thermal expansion | ISO 11359-2 | 6.5E-05 cm/cm/°C | |
ISO 11359-2 | 6.5E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.