ABS 440Y MH1 TORAY MALAYSIA
100
Form:Granules | Grade:Injection grade
Properties:
heat-resistingHigh temperature resistan
Typical Applications:
Electronic fieldElectrical fieldAutomotive sector
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Electronic field | Electrical field | Automotive sector |
| Properties: | heat-resisting | High temperature resistan |
Certificates

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 15 | kJ/m² |
| Impact strength of cantilever beam gap | 23°C,3.20mm | ASTM D256 | 190 | J/m |
| 23°C,12.7mm | ASTM D256 | 170 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ASTM D790 | 77.0 | Mpa | |
| ISO 178 | 83.0 | Mpa | ||
| Tensile modulus | ISO 527-2/1 | 2800 | Mpa | |
| tensile strength | Yield | ASTM D638 | 49.0 | Mpa |
| Yield | ISO 527-2/50 | 53.0 | Mpa | |
| elongation | Break | ASTM D638 | 22 | % |
| Tensile strain | Break | ISO 527-2/50 | >10 | % |
| Bending modulus | ASTM D790 | 2400 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed,6.40mm | ASTM D648 | 98.0 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 92.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.06 | g/cm³ | |
| ISO 1183 | 1.06 | g/cm³ | ||
| melt mass-flow rate | 220°C/10.0kg | ISO 1133 | 10 | g/10min |
| Shrinkage rate | MD | ASTM D955 | 0.40-0.70 | % |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 115 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.