PP Toler PP PP4390 USA Toler

0
  • Usages:
    Applications in the automotive industry household goods general use medical equipment
  • Compare

Technical Data Sheet

impact performanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gap23°C,InjectionASTM D256A37 J/m
mechanical propertiesTest ConditionTest MethodTest Result
Bending modulusInjectionASTM D790A1300 MPa
elongationYieldASTM D63811to13 %
tensile strengthYield,InjectionASTM D63834.0 MPa
thermal performanceTest ConditionTest MethodTest Result
Hot deformation temperature0.45MPa,UnannealedASTM D64897.0 °C
Physical propertiesTest ConditionTest MethodTest Result
melt mass-flow rate230°C/2.16kgASTM D12383.0to4.0 g/10min
densityASTM D15050.900 g/cm³
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessR-ScaleASTM D78583to87
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.