PA/ABS N NM-13 BASF USA
49
Form:Granules | Grade:Injection grade
Properties:
Low temperature resistancHigh impact resistance
Typical Applications:
Low temperature applicationssporting goods
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Low temperature applications | sporting goods |
| Properties: | Low temperature resistanc | High impact resistance |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Tensile strain | Yield,23°C | ISO 527-2 | 3.4 | % |
| tensile strength | Yield,23°C | ISO 527-2 | 35.0 | Mpa |
| Tensile modulus | ISO 527-2 | 1600 | Mpa | |
| bending strength | ISO 178 | 50.0 | Mpa | |
| Bending modulus | ISO 178 | 1500 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 1E-04 | cm/cm/°C |
| Vicat softening temperature | -- | ISO 306/B50 | 91.0 | °C |
| -- | ISO 306/A50 | 165 | °C | |
| Hot deformation temperature | 1.8MPa,Annealed | ISO 75-2/A | 58.0 | °C |
| 0.45MPa,Annealed | ISO 75-2/B | 80.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 1.1 | % |
| Shrinkage rate | ISO 294-4 | 0.80 | % | |
| Melt Volume Flow Rate (MVR) | 240°C/10.0kg | ISO 1133 | 25.0 | cm3/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | ||
| Dissipation factor | 1MHz | IEC 60250 | 0.015 | |
| Relative permittivity | 1MHz | IEC 60250 | 2.90 | |
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | 1E+14 | ohms | |
| film | Test Condition | Test Method | Test Result | Test Unit |
| elongation | Break | ISO 527-3 | >50 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.