Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792 | 1.19 g/cm³ |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ASTM D638 | 1800 MPa | |
tensile strength | Yield | ASTM D638 | 40.0 MPa |
elongation | Break | ASTM D638 | >100 % |
Flexural modulus | ASTM D790 | 1900 MPa | |
bending strength | ASTM D790 | 70.0 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ISO 180/A | 50 kJ/m² | |
Suspended wall beam without notch impact strength | ISO 180 | 无断裂 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
RTI Elec | UL 746 | 80.0 °C | |
RTI Imp | UL 746 | 80.0 °C | |
RTI | UL 746 | 80.0 °C | |
Heat distortion temperature | ASTM D648A | 80.0 °C | |
vicat | ASTM D15252 | 110 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.