POM C9021 10/1570 CELANESE USA
132
Form:Granules | Grade:Impact resistant grade
Properties:
wear resistant
Typical Applications:
Thin walled productshousehold electrical appliancesAutomotive ApplicationsFitness equipment
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Thin walled products | household electrical appliances | Automotive Applications | Fitness equipment |
| Properties: | wear resistant |
Certificates
No Data...
Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| characteristic | 通用注塑级 | |||
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 8.5cm | ISO 1133 | 12.07 | g/10min |
| Water absorption rate | Saturation23℃ | ISO 62 | 0.75 | % |
| 23℃and50%RH | ISO 62 | 0.2 | % | |
| density | ISO 1183 | 1.42 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile creep modulus | 1000 hours | ISO 899 part 1 | 1200 | Mpa |
| 1 hour | ISO 899 part 1 | 2400 | Mpa | |
| Charpy Notched Impact Strength | 23℃ | ISO 179 1eA | 0.6 | J/cm |
| Impact strength of simply supported beam without notch | 低温-30℃ | ISO 179 1eU | 12 | J/cm |
| Charpy Notched Impact Strength | 低温-30℃ | ISO 179 1eA | 0.6 | J/cm |
| Impact strength of simply supported beam without notch | 23℃ | ISO 179 1eU | 12.0 | J/cm |
| Bending modulus | ISO 178 | 2700 | Mpa | |
| Tensile modulus | 1mm/min | ISO 527 part 1/2 | 2800 | Mpa |
| elongation | 伸长率 | ISO 527 part 1/2 | 9.0 | % |
| Elongation at Break | 50mm/min | ISO 527 part 1/2 | 20 | % |
| tensile strength | 50mm/min,Yield | ISO 527 part 1/2 | 65 | Mpa |
| Ball Pressure Test | 30sec数值 | ISO 2039 part 1 | 140 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | 23-55℃ Longitudinal | ISO 11359 part 1/2 | 110 | µm/m-℃ |
| Melting temperature | DSC,10 K/min | ISO 3146 method C1b | 166 | °C |
| Hot deformation temperature | 1.8MPa | ISO 75 part 1/2 | 100 | °C |
| Vicat softening temperature | VST/B/50 | ISO 306 | 150 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | ASTM D1238/ISO 1133 | 8 | g/10min | |
| Shrinkage rate | ASTM D955 | 1.8 | % | |
| density | ASTM D792/ISO 1183 | 1420 | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 低频100 Hz | IEC 60250 | 0.0025 | |
| IEC 60250 | 0.008 | 1 MHz | ||
| Dielectric strength | IEC 60243 part 1 | 35 | KV/mm | |
| Dielectric constant | 低频100 Hz | IEC 60250 | 4.20 | |
| 1 MHz | IEC 60250 | 4.20 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.