PA46 CR310 NA DSM HOLAND
31
Form:Granules | Grade:Flame retardant and high temperature resistant grade
Properties:
Thermal stabilityFlame retardant
Typical Applications:
CastersFitness equipment
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Casters | Fitness equipment |
| Properties: | Thermal stability | Flame retardant |
Certificates
No Data...
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Flammability level | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 12500 | Mpa | |
| tensile strength | Break | ISO 527-2 | 140 | Mpa |
| Tensile strain | Break | ISO 527-2 | 1.7 | % |
| Bending modulus | ISO 178 | 12500 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 290 | °C |
| 1.8 MPa, Unannealed | ISO 75-2/A | 290 | °C | |
| Melting temperature | ISO 11357-3 | 295 | °C | |
| Linear coefficient of thermal expansion | Flow | ISO 11359-2 | 3.5E-5 | cm/cm/°C |
| Across Flow | ISO 11359-2 | 4.5E-5 | cm/cm/°C | |
| RTI Elec | 0.75 mm | UL 746 | 65.0 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | 横向Flow | ISO 294-4 | 1.0 | % |
| Flow | ISO 294-4 | 0.40 | % | |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 1.8 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | > 1.0E+15 | ohms·cm | |
| Dielectric strength | IEC 60243-1 | 33 | KV/mm | |
| Relative permittivity | 1 MHz | IEC 60250 | 4.10 | |
| 1.00 GHz | IEC 60250 | 3.90 | ||
| Compared to the anti leakage trace index | IEC 60112 | V |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.