PPA HTN FR52G30NH NC010 DUPONT SHENZHEN
198
Form:Granules | Grade:Enhanced level
Properties:
High temperature resistanAging resistanceFlame retardant
Typical Applications:
Automotive interior equipmentProfilebuilding materials
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive interior equipment | Profile | building materials |
| Properties: | High temperature resistan | Aging resistance | Flame retardant |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | kJ/m² | 40 | |
| 23°C | kJ/m² | 45 | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Flammability level | 0.400mm | V-0 | -- | |
| 1.50mm | V-0 | -- | ||
| Burning wire flammability index | 0.400mm | °C | 960 | -- |
| 3.00mm | °C | 960 | -- | |
| Hot filament ignition temperature | 0.400mm | °C | 700 | -- |
| 3.00mm | °C | 775 | -- | |
| Extreme Oxygen Index | % | 37 | -- | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | MPa | 10700 | 11300 | |
| tensile strength | Break | 145 | MPa | |
| Tensile strain | Break | % | 2.1 | 1.9 |
| Bending modulus | MPa | 9800 | 10800 | |
| bending strength | 225 | MPa | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Elec | 0.400mm | °C | 140 | -- |
| 0.750mm | °C | 140 | -- | |
| 1.50mm | °C | 140 | -- | |
| 3.00mm | °C | 140 | -- | |
| Linear coefficient of thermal expansion | TD:55to160°C | cm/cm/°C | 9.5E-05 | -- |
| TD:-40to23°C | cm/cm/°C | 6E-05 | -- | |
| TD | cm/cm/°C | 6.2E-05 | -- | |
| MD:55to160°C | cm/cm/°C | 1.2E-05 | -- | |
| MD:-40to23°C | cm/cm/°C | 1.8E-05 | -- | |
| MD | cm/cm/°C | 1.8E-05 | -- | |
| Melting temperature | °C | 310 | -- | |
| Hot deformation temperature | 1.8MPa,Unannealed | °C | 281 | -- |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | TD | % | 1.0 | -- |
| MD | % | 0.30 | -- |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.