PP 9C21120 FR5 4Plas
Properties:
Filler reinforcement material talc filler 20% filler by weight characteristics copolymer halogen-free
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | reinforcement material | talc filler | 20% | filler by weight characteristics | copolymer | halogen-free |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 5.0 | kJ/m² |
| 23°C | ISO 180/1A | 15 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.60 mm | UL 94 | V-2 | |
| Burning wire flammability index | 2.00 mm | IEC 60695-2-12 | 960 | °C |
| UL flame retardant rating | 1.6mm | UL 94 | V-0 | |
| Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 960 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23°C | ISO 527-2/5 | 3500 | MPa |
| tensile strength | Break, 23°C | ISO 527-2/5 | 20 | MPa |
| Tensile strain | Break, 23°C | ISO 527-2/5 | 10 | % |
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 5 | kJ/m² |
| 23°C | ISO 180/1A | 15 | kJ/m² | |
| Tensile modulus | 23°C | ISO 527-2/5 | 3500 | MPa |
| tensile strength | Break,23°C | ISO 527-2/5 | 20.0 | MPa |
| Tensile strain | Break,23°C | ISO 527-2/5 | 10 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 11357 | 165 | °C | |
| ISO 11357 | 165 | °C | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.36 | g/cm³ | |
| melt mass-flow rate | 230°C/2.16 kg | ISO 1133 | 15 | g/10 min |
| density | ISO 1183 | 1.36 | g/cm³ | |
| melt mass-flow rate | 230°C/2.16kg | ISO 1133 | 15 | g/10min |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.