PBT PB70 GR20 MELOS GERMANY
16
Form:Granules | Grade:Flame retardant grade
Properties:
Low friction coefficientImpact resistanceThermal insulationAging resistanceHigh glossDimensional stabilityFiller: Glass fiber reinf20% filler by weight
Typical Applications:
Electronic fieldElectrical field
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electronic field | Electrical field |
| Properties: | Low friction coefficient | Impact resistance | Thermal insulation | Aging resistance | High gloss | Dimensional stability | Filler: Glass fiber reinf | 20% filler by weight |
Certificates
No Data...
Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| characteristic | 加纤20% 增强级 | |||
| purpose | 连接器插件 | |||
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Suspended wall beam without notch impact strength | -30°C | ISO 180/1U | 60 | kJ/m² |
| 23°C | ISO 180/1U | 65 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.75mm | UL 94 | V-2 | |
| 1.6mm | UL 94 | V-0 | ||
| Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 960 | °C |
| Hot filament ignition temperature | 2.0mm | IEC 60695-2-13 | 725 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23°C | ISO 527-2 | 7500 | Mpa |
| tensile strength | Break,23°C | ISO 527-2 | 100 | Mpa |
| Tensile strain | Break,23°C | ISO 527-2 | 3.0 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 215 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 175 | °C | |
| Melting temperature | ISO 11357-3 | 225to255 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.20 | % |
| water content | ISO 15512 | <0.080 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1E+14 | ohms | |
| Volume resistivity | IEC 60093 | 1E+16 | ohms·cm | |
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | PLC 3 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.