PA6 Nylux 6G33XE KMI Group, Inc.
Properties:
Filler glass fiber reinforced material 33% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 33% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ISO 180 | 190 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.8mm | UL 94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ASTM D638 | 8.96 | MPa | |
| elongation | Yield | ASTM D638 | 2.0 | % |
| tensile strength | Yield | ASTM D638 | 0.131 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 3146 | 220 | °C | |
| Vicat softening temperature | ISO 306/B50 | 210 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 205 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 215 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium | ASTM D570 | 1.3 | % |
| Shrinkage rate | MD | ASTM D955 | 1.2to1.8 | % |
| density | ASTM D792 | 1.29 | g/cm³ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.