Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D-792 | 无水|1.59 |
density | | ASTM D-792 | 1.3%水|- |
density | | g/cm³ | 1.59 -- |
Shrinkage rate | | % | 0.60到0.90 -- |
Shrinkage rate | | % | 0.20到0.50 -- |
Water absorption rate | | % | 0.60 -- |
Water absorption rate | | % | 4.0 -- |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | | 121 -- |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | | V-0 -- |
Basic performance | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTM D-570 | 无水|0.4 % |
Water absorption rate | | ASTM D-570 | 1.3%水|- % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
IZOD impact strength | | | 无水|65 kg.cm/cm |
IZOD impact strength | | | 1.3%水|70 kg.cm/cm |
Tensile fracture strength | | ASTM D-638 | 无水|1640 kg/cm2 |
Tensile fracture strength | | ASTM D-638 | 1.3%水|1350 kg/cm2 |
elongation at break | | ASTM D-638 | 无水|5 % |
elongation at break | | ASTM D-638 | 1.3%水|5 % |
| | ASTM D-790 | 无水|2490 kg/cm2 |
| | ASTM D-790 | 1.3%水|2000 kg/cm2 |
flexural modulus | | ASTM D-790 | 无水|93200 kg/cm2 |
flexural modulus | | ASTM D-790 | 1.3%水|65000 kg/cm2 |
Tensile strain | | % | 2.5 -- |
Tensile strain | | % | 3.0 3.0 |
Tensile strain | | % | 4.5 -- |
Flexural modulus | | MPa | 10200 -- |
Flexural modulus | | MPa | 9300 6500 |
Flexural modulus | | MPa | 5500 -- |
Bending stress | | MPa | 275 -- |
Bending stress | | MPa | 250 |
Bending stress | | MPa | 150 -- |
| | mg | 26.0 -- |
Tensile stress | | MPa | 190 -- |
Tensile stress | | MPa | 165 |
Tensile stress | | MPa | 110 -- |
Other performance | Test Condition | Test Method | Test Result |
---|
| | | 无水|30 wt% |
| | | 1.3%水|- wt% |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | kJ/m² | 7.0 -- |
Charpy Notched Impact Strength | | kJ/m² | 9.5 14 |
Impact strength of simply supported beam without notch | | kJ/m² | 65 70 |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | ASTM D-257 | 1.3%水|8×1013 Ω.cm |
dielectric strength | | ASTM D-149 | 无水|38 KV/mm |
dielectric strength | | ASTM D-149 | 1.3%水|33 KV/mm |
IEC Conductive Track Index | | UL 746 | 无水|200 V |
IEC Conductive Track Index | | UL 746 | 1.3%水|- V |
Loss factor | | ASTM D-150 | 无水|0.003-0.009 |
Loss factor | | ASTM D-150 | 1.3%水|- |
arc resistance | | ASTM D-495 | 无水|70-80 S |
arc resistance | | ASTM D-495 | 1.3%水|- S |
Volume resistivity | | ASTM D-257 | 无水|8×1014 Ω.cm |
Volume resistivity | | ohms·cm | 1E+15 1E+13 |
dielectric strength | | kV/mm | 38 33 |
dielectric constant | | | 4.00 -- |
dielectric constant | | | 0.0100 -- |
Arc resistance 6 | | sec | 70.0 -- |
Compared to the Leakage Tracking Index (CTI) | | V | 200 -- |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTM D-696 | 无水|2 10-5cm/cm.℃ |
| | ASTM D-696 | 1.3%水|- |
heat deflection temperature | | ASTM D-648 | 无水|251 °C |
heat deflection temperature | | ASTM D-648 | 1.3%水|- °C |
melting point | | 差示扫描测热计DSC法 | 无水|265 °C |
UL-94 flame retardant grade | | UL 94 | 无水|V-0 |
UL-94 flame retardant grade | | UL 94 | 1.3%水|- |
| | °C | 251 -- |
melting temperature | | °C | 265 -- |
| | cm/cm/°C | 2E-05 -- |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.