plas
Log In

LDPE AEI SX409:CM401 UK AEI Compounds

0

Technical Data Sheet

mechanical propertiesTest ConditionTest MethodTest Result
tensile strengthIEC 60811-1-118.0 MPa
Tensile strainBreakIEC 60811-1-1350 %
thermal performanceTest ConditionTest MethodTest Result
Cold bend-70°CIEC 60811-1-4pass
Physical propertiesTest ConditionTest MethodTest Result
melt mass-flow rate190°C/2.16kgInternal Method0.60to0.90 g/10min
densityBS2782620A0.928 g/cm³
Electrical performanceTest ConditionTest MethodTest Result
Dissipation factor23°CIEC 602504E-04
Relative permittivity23°C,50HzIEC 602502.50
Dielectric strength20°CIEC 60243-121 kV/mm
Volume resistivity20°CIEC 60502>1.0E+16 ohms·cm
agingTest ConditionTest MethodTest Result
Tensile stress change rate135°C,168hr,BreakIEC 60811-1-2-2.0 %
Change rate of tensile strength in air135°C,168hrIEC 60811-1-24.0 %
Supplementary InformationTest ConditionTest MethodTest Result
CureTime1.50cmIEC 60811-2-1280.0 hr
CureTime8.00mmIEC 60811-2-1190.0 hr
CureTime3.00to6.00mmIEC 60811-2-16.0to24.0 hr
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.